Generator 8002

The twin generators of the 8002 series represent a new generation of corona generators for the medium to high power segment. The generators are characterized by their robust, user friendly, and easy to maintain stand alone design as well as various innovative hard and software features. In combination with a corona treating station, material surfaces are functionalised to guarantee adhesion in many converting applications.

Two independently adjustable power out-puts make the 8002 series especially suitable for double side treatments and skip treatments in high speed printing presses.

Technical Data

Corona power                         2x2 kW to 2x7 kW

Corona frequency range           20 – 40 kHz

Mains voltage, standard             3 x 400 V

Mains voltage, special               On request

Mains frequency                        50/60 Hz

Protection                                  IP 43

Generator weight                        approx. 120 kg

Generator dimensions (WxHxD, mm) 4-8 kW:600x1600x500; 10-14 kW:600x2000x500

Technical Features

Two independently adjustable power outputs

Universal use for corona applications

Touch screen operator panel

Short circuit proof IGBT output stage

Output efficiency greater than 95 %

Regulator circuit to stabilize output power

Easy to service and robust stand alone design

Connectors for emergency stop, remote control, corona station

Three inputs, programmable via operator panel

Outputs for operating status displays

Four outputs, programmable via operator panel

Diagnostic memory

Xenon beacon for optical fault indication

Power connection with screened cables

Roll rotation monitor with selectable minimum speed

Soft Corona Start (SCS). Enables generator start-up with wet treating electrode

Programmable Corona Alarm (PCA). Freely selectable min/max output alarm

CCP – Controlled Corona Power factor. Speed dependent energy control

SCT – Skip Corona Treatment. Control unit for skip treatment

DCR – Duty Cycle Regulation. Pulse mode for homogeneous corona discharge under extreme treating conditions

Customer specific bus control

Remote control panel in various versions

Connection for ozone extraction system

Customer specific potential free inputs and outputs

Remote diagnostics via modem

CAN- and Profibus connections

Generator 8002