Generator 60500
Technical Data
Corona power 10.0 – 50.0 kW
Corona frequency range 18 – 40 kHz
Max. power input 55 kVA
Mains voltage, standard 3 x 400 V
Mains voltage, special On request
Mains frequency 50/60 Hz
Protection IP 43
Weight: Generator control cabinet approx. 270 kg
Weight: Generator output cabinet approx. 125 kg
Dimensions: Generator control (WxHxD) 1000 x 2000 x 400 mm
Dimensions: Generator output (WxHxD) 800 x 1400 x 400 mm
Weight: Output transformer approx. 150 kg
Dimensions: Output transformer (WxHxD) 1500 x 280 x 270 mm
Technical features
Designed for use in large systems
Alphanumeric touch pad for control / display
Short circuit proof IGBT output stage
Output stage efficiency greater than 95 %
Control circuit stabilizes output value
Checking, displaying and logging of all operational data of the output stage
Extensive fault diagnosis
Inputs for emergency stop, remote control, corona station
Control cabinet technology designed to meet service requirements
Compact output power stage in separate cabinet
Power connection with screened cables
Roll rotation monitor with selectable minimum speed
Customizing flexibility
Soft Corona Start (SCS). Enables generator start-up with wet treating electrode
Programmable Corona Alarm (PCA). Freely selectable min/max
output alarm
CCP – Controlled Corona Power factor. Speed dependent energy control
DCR – Duty Cycle Regulation. Pulse mode for homogeneous corona discharge under extreme treating conditions
Remote control panel in various versions
Protection IP 54
PROFI-bus communication module, others on request
Telediagnostic service via modem
Change-over Switch between two output transformers (external accessory unit)